RCC 2 Way Slab Design (IS-456-2000)
Prepared by :- #abilas
2 way slab Design should be preferred
Inputs | Outputs |
---|---|
Material characteristics, Slab Dimensions, Loads Applied | Design Material Requirement |
CalculatorCivil |
CalculatorCivil.com |
|||||||||||
Project Name:- |
RCC Framed Structure Building |
Proj. no.- |
220001 |
|||||||||
Structure Details:- |
Two Way RCC Slab (In Framed Structure) Design |
Cal. By:- |
ASG |
Date:- |
4/7/2022 |
|||||||
Design Note no.:- |
Owner-Client-Structure_abbrevation-Dgn_note_no.1 |
Chk. By:- |
RPP |
Rev no.:- |
R0 |
|||||||
Slab Design (S1) |
||||||||||||
1 |
Input Data |
|||||||||||
Long Span (Ly) |
= |
m |
||||||||||
Short Span (Lx) |
= |
m |
||||||||||
Panel size |
= |
6
|
x |
4.32
|
||||||||
Concrete Grade (fck) |
= |
Mpa |
||||||||||
Steel Grade (fy) |
= |
Mpa |
||||||||||
Clear Cover (Cc) |
= |
mm |
||||||||||
Ly/Lx |
= |
1.39
|
Two-way
|
|||||||||
Edge Condition. |
5
|
|||||||||||
(Refer P.No.-91, Table 26, IS:456-2000) |
||||||||||||
2 |
Load calculations |
|||||||||||
Assume D |
= |
mm |
||||||||||
Assume Eff. Cover (Ceff) |
= |
30
|
mm |
|||||||||
Dead load of slab |
= |
D x 25 |
||||||||||
= |
3.75
|
kN/m2 |
||||||||||
Floor finish + Superimposed Dead Loads |
= |
kN/m2 |
||||||||||
Live load |
= |
kN/m2 |
||||||||||
Total load (W) |
= |
7.75
|
kN/m2 |
|||||||||
Ast min = |
0.0012 x D x 1000 |
= |
180
|
mm2/m |
(As per clause 26.5.2.1, IS 456-2000) |
|||||||
3 |
Force/ Moments calculations |
|||||||||||
αx (+ve) |
= |
0.043
|
(Refer P.No.-91, Table 26, IS:456-2000) |
|||||||||
αx (-ve) |
= |
0.056
|
||||||||||
αx (+ve) |
= |
0.035
|
||||||||||
αx (-ve) |
=
|
0.000
|
||||||||||
The Factored Moments are
|
Moment |
Ast calc. |
Ast reqd. |
8 mm @ |
10 mm @ |
12 mm @ |
||||||
(kNm) |
(mm2/m) |
(mm2/m) |
c/c in mm |
c/c in mm |
c/c in mm |
|||||||
Mx(+ve) at midsan = αx(+ve) W lx2 1.5 =
|
9.293
|
182.750
|
182.750
|
273.160
|
300.000
|
300
|
||||||
Mx(-ve) at support = αx(-ve) W lx2 1.5 =
|
12.251
|
243.005
|
243.005
|
205.428
|
300.000
|
300.000
|
||||||
My(+ve) at midspan = αy(+ve) W lx2 1.5 =
|
7.593264
|
148.605
|
180.000
|
277.333
|
300
|
300
|
||||||
My(-ve) at support= αy (-ve) W lx2 1.5 =
|
0
|
0.000
|
180.000
|
277.333
|
300.000
|
300
|
||||||
Maximum C/C spacing between Primary Bars is 300, 3d mm |
(As per clause 26.3.3.b1 , IS 456-2000) |
|||||||||||
Maximum C/C spacing between Secondary Bars is 450, 5d mm |
(As per clause 26.3.3.b2 , IS 456-2000) |
|||||||||||
4 |
Design of Slab |
|||||||||||
d required |
= |
\[\sqrt{(M_u 10^6)/(0.133 f_{ck} b)} =\] |
55.410
|
mm |
||||||||
D provided |
= |
mm |
||||||||||
dx provided |
= |
120
|
mm |
(for shorter span reinforcement) |
||||||||
dy provided |
= |
110
|
mm |
(for longer span reinforcement) |
Safe
|
|||||||
Dia of bar(mm) |
Spacing (mm) |
Ast prov. in mm2/m |
||||||||||
Provide 150 mm Thick Slab
|
Ast for shorter span @ midspan(+Mx) = |
mm dia bar @ c/c |
520
|
Safe
|
||||||||
Ast for shorter span @ support (-Mx) = |
mm dia bar @ c/c |
520
|
Safe
|
|||||||||
Ast for longer span @ midspan (+My) = |
mm dia bar @ c/c |
520
|
Safe
|
|||||||||
Ast for longer span @ support (-My) = |
mm dia bar @ c/c |
520
|
Safe
|
|||||||||
Maximum C/C spacing between Primary Bars = 150 mm
|
OK
|
(As per clause 26.3.3.b1 , IS 456-2000) |
||||||||||
Maximum Dia of Bars is D/8 = 18.75 mm
|
OK
|
(As per clause 26.5.2.2 , IS 456-2000) |
||||||||||
5 |
Check for Deflection : |
|||||||||||
Percentage of Tension renforcement |
= |
0.433333333
|
% |
|||||||||
fs = |
0.58 fy Area of c/s of steel required |
= |
101.918
|
MPa (Refer P.No.-38, IS-456-2000) |
||||||||
Area of c/s of steel provided |
||||||||||||
Span/ eff. Depth ratio (Lx/d) |
= |
(As per clause 23.2.1, IS-456-2000) |
||||||||||
Modification factor = |
1 |
= |
3.07
|
|||||||||
0.225 + 0.00322 fs - 0.625 log10(bd/(100Ast)) |
||||||||||||
Allowable Span/eff. Depth ratio |
= |
70.61
|
||||||||||
Effective Depth (dx) required |
= |
61.181
|
mm |
Safe
|
||||||||
Overall Depth (D) required |
= |
91.181
|
mm |
Safe
|
||||||||
6 |
Check for Shear : |
|||||||||||
a |
At Short direction |
|||||||||||
Vu (Short dir.) = 1.33 (1.5 W Lx/4) |
= |
16.74
|
kN |
|||||||||
Ï„v = Vu / bd = |
0.140
|
MPa |
||||||||||
pt. % |
= |
0.433333333
|
||||||||||
β |
= |
8.038
|
Refer P.No.-175, SP 16, β = max(0.8 fck / (6.89 pt.), 1) |
|||||||||
Ï„c (Table 19) |
= |
0.468
|
MPa |
Refer P.No.-175, SP 16, τc =[0.85 sqrt(0.8 fck)(sqrt(1+ 5β)-1)] / 6β |
||||||||
k |
= |
1.3
|
(As per clause 40.2.1.1, IS 456-2000) |
|||||||||
k Ï„c |
= |
0.608
|
Safe
|
|||||||||
b |
At Long direction |
|||||||||||
Vu (Long dir.) = 1.33 (1.5 W (Lx Ly/2-Lx Lx/4))/Ly |
= |
21.427
|
kN |
|||||||||
Ï„v = Vu / bd = |
0.195
|
MPa |
||||||||||
pt. % |
= |
0.473
|
% |
|||||||||
β |
= |
7.369
|
Refer P.No.-175, SP 16, β = max(0.8 fck / (6.89 pt.), 1) |
|||||||||
Ï„c (Table 19) |
= |
0.485
|
MPa |
Refer P.No.-175, SP 16, τc =[0.85 sqrt(0.8 fck)(sqrt(1+ 5β)-1)] / 6β |
||||||||
k |
= |
1.3
|
(As per clause 40.2.1.1 , IS 456-2000) |
|||||||||
k Ï„c |
= |
0.631
|
MPa |
Safe
|
Moments Considered |
Short Span Coefficients αx |
Long Span |
|||||||||||||
Coeff αy |
|||||||||||||||
Values of ly/lx |
ly/lx |
||||||||||||||
1.0 |
1.1 |
1.2 |
1.3 |
1.4 |
1.5 |
1.75 |
2.0 |
||||||||
Values of ly/lx |
|||||||||||||||
Two Short Edges Discontinuous
|
5A
|
Negative Moment-5
|
0.045
|
0.049
|
0.052
|
0.056
|
0.059
|
0.060
|
0.065
|
0.069
|
0.000
|
||||
5B
|
Positive Moment-5
|
0.035
|
0.037
|
0.040
|
0.043
|
0.044
|
0.045
|
0.049
|
0.052
|
0.035
|
|||||
k |
|||||||||||||||
D |
|||||||||||||||